FPI P36-NG3 Owners & Installation Manual page 26

P36 zero clearance direct vent gas fireplace
Table of Contents

Advertisement

INSTALLATION
One 90
o
elbow = Two 45
Option V
H
A)
0' Min.
2' Max. 1' Min.
B)
1' Min.
4' Max. 2' Min.
C)
2' Min.
5' Max. 3' Min.
D)
3' Min.
6' Max. 4' Min.
E)
4' Min.
7' Max. 5' Min.
F)
5' Min.
8' Max. 6' Min.
Lengths do not include elbow indicated
For additional vertical venting with 2 x 90
V1
H1
26
Vertical Venting with Two (2) 90
o
elbows.
V + V1
With these options, max.
total pipe length is 30 feet
with min. of 6 feet total
vertical and max. 8 feet
total horizontal.
Please note min. 1 foot
between 90
o
elbows is
required.
o
elbows, refer to next page.
Vertical Venting with Three (3) 90
V
H
o
Elbows
V1
o
Elbows
o
One 90
elbow = Two 45
Option
V
H + H1 V + V1
A)
0' Min.
2' Max. 2' Min.
B)
1' Min.
2' Max. 3' Min.
C)
2' Min.
3' Max. 4' Min.
D)
3' Min.
4' Max. 6' Min.
E)
4' Min.
5' Max. 7' Min.
F)
5' Min.
6' Max. 8' Min.
G)
6' Min.
7' Max.
H)
7' Min.
8' Max. 10' Min.
Lengths do not include
elbow indicated
FPI P36-3 Zero Clearance Direct Vent Gas Fireplace
V
H
o
elbows.
With these options, max.
total pipe length is 30 feet
with min. of 10 feet total
vertical and max. 8 feet
total horizontal.
Please note min. 1 foot
between 90
o
elbows is
9' Min.
required.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P36-lp3

Table of Contents