Top Section Burner Valve And Nozzle Check, Replacement - Vulcan-Hart EG160 Service Manual

Gas restaurant range
Table of Contents

Advertisement

TOP SECTION BURNER VALVE AND NOZZLE CHECK,
REPLACEMENT
TOP SECTION BURNER VALVE CHECK
After a long period of use on the range, the top section burner valve can show signs of wear. Check valve for gas leakage
and sloppy valve control. Check also for valve nozzle blockage or damage.
TOP SECTION BURNER VALVE AND NOZZLE REPLACEMENT
TOOLS REQUIRED:
1
" open end wrench, 6" adjustable wrench or standard pipe wrench,
1
" socket and socket driver.
2
4
1. Disconnect main unit gas supply.
2. Remove control panel cover and top grates or griddle section.
3. Remove and check valve and valve nozzle for obstructions and damage.
4. Remove obstruction, or if necessary, replace nozzle or entire valve. When reinstalling, or if the installation of a new
valve is required, be sure to use pipe thread sealant on the threaded end which engages the manifold pipe.
– 36 –