Lighting And Shutting Down Pilots; Open Top, Griddle Top And Hot Top Burner Pilots; Standard Oven Pilot - Vulcan-Hart GH30 Service Manual

Gh series heavy duty gas ranges
Table of Contents

Advertisement

LIGHTING AND SHUTTING DOWN PILOTS

OPEN TOP, GRIDDLE TOP AND HOT TOP BURNER PILOTS

1. Turn main gas supply ON.
2. Turn all top burner valve knobs ON to purge gas line of air.
3. Turn top burner valve knobs OFF.
4. Wait 30 seconds.
5. Using a taper, light the pilot(s).
6. If pilot fails to light, wait 5 minutes and repeat Steps 1 through 5.
7. Turn one top burner valve ON to ensure that all gas lines are completely purged of air. Turn burner
OFF when gas begins to flow.
Nightly Shutdown: Turn burner valve OFF; pilot will remain lit.
Complete Shutdown: Turn burner valve OFF; pilot will remain lit. Turn main gas valve OFF.

STANDARD OVEN PILOT

Before lighting oven, be sure that range top sections have been lit.
1. Open oven door and locate square pilot lighter cutout.
2. Using a taper, light oven pilot by depressing red ignition button (Fig.1) located on the side control
panel above the thermostat knob. Light pilot and continue to hold ignition button in for one minute.
If pilot fails to light, turn main gas valve OFF and wait 5 minutes before repeating Steps 1 and 2.
3. Set oven thermostat to desired temperature.
Fig. 1
- 10 -
PL-40052

Advertisement

Table of Contents
loading