3. Remove valve from range manifold.
4. With pipe thread sealant covering the threads, install new pilot valve by reversing Steps 1 through 3.

TOP SECTION BURNER VALVE AND NOZZLE CHECK

After a long period of use on the range, the top section burner valve can show signs of wear. Check
valve for gas leakage and sloppy valve control. Check also for valve nozzle blockage or damage.

TOP SECTION BURNER VALVE AND NOZZLE REPLACEMENT

Tools Required:
1
" open end wrench, 6" adjustable wrench or standard pipe wrench,
2
socket driver.
1. Disconnect main gas supply and allow to cool.
2. Remove control panel cover and top grates or griddle section.
3. Remove and check valve and valve nozzle for obstructions and damage.
4. Remove obstruction, or if necessary, replace nozzle or entire valve. When reinstalling, or if the
installation of a new valve is required, be sure to use pipe thread sealant on the threaded end which
engages the manifold pipe.

SERVICE AND PARTS INFORMATION

To obtain additional service and parts information concerning the MG Series Gas Restaurant Modular
and Step-up Range, contact the Vulcan-Hart Service Depot in your area (refer to listing supplied with
this range), or Vulcan-Hart Company Service Department at the address or phone number shown on
the front cover of this manual.