STANDARD OVEN & GRIDDLE
THERMOSTAT REPLACEMENT (Cont.)
4. From inside the oven, straighten the capillary lead. From the opening in the oven top section, pull the capillary out of
the oven cavity (Fig. 29).
5. Remove the top section burner valve knobs, top grates and aeration plate. (Figs. 30)
6. Remove screws holding the control panel in place.
7. Disconnect the thermostat burner tubing (Fig. 31).
8. Remove top burners, if required, to access the thermostat.
Fig. 30
Fig. 31
– 26 –