Griddle Thermostat Checks And Calibration; Griddle Thermostat Replacement - Vulcan-Hart MG12 Service Manual

Gas restaurant range
Table of Contents

Advertisement

GRIDDLE THERMOSTAT CHECKS AND CALIBRATION

Refer to GRIDDLE THERMOSTAT ADJUSTMENTS in this manual for the procedures for checking and
calibrating the thermostat for the griddle.

GRIDDLE THERMOSTAT REPLACEMENT

Tools Required: Pipe wrench, 6" adjustable wrench,
socket wrench.
1. Disconnect range gas supply and allow range to cool.
2. Tilt the front of the griddle up and carefully slide the capillary bulb from the Y-shaped mounting guides
on the underside of the griddle assembly (Fig. 15).
3. Remove griddle assembly.
4. Remove burner valve knobs (Fig. 16).
5. Remove (4) screws holding the control panel in place.
6. Remove burner and pilot tubing (Fig. 17).
1
" flat blade screwdriver,
8
Fig. 15
– 16 –
5
" socket, and
16

Hide quick links: