Virtual Fabrics considerations for ICLs

FIGURE 59
The following ICL connections are not allowed:

ICL trunking on the Brocade DCX and DCX-4S

On the Brocade DCX and DCX-4S, trunks are automatically formed on the ICLs when you install the
ISL Trunking license on each platform. The ICLs are managed the same as ISL trunks.
Follow the guidelines in the hardware reference manuals for connecting the ICL cables.
Virtual Fabrics considerations for ICLs
In Virtual Fabrics, the ICL ports can be split across the logical switch, base switch, and default
switch. The triangular topology requirement must be met for each fabric individually.
The following restrictions apply:
396
DCX-4S allowed ICL connections
ICL0 ports to ICL0 ports
ICL1 ports to ICL1 ports
On the Brocade DCX, each ICL is managed as two 8-port ISL trunks.
On the Brocade DCX-4S, each ICL is managed as one 8-port ISL trunk.
ICL ports cannot be in a logical switch that is using XISLs. The "Allow XISL Use" attribute for the
switch must be off.
All of the user ports in an ICL cable must be in the same logical switch. Distributing the user
ports within the same cable across multiple logical switches is not supported.