Testing Distress Button

6-4
The DISTRESS button on the IC-302 may be tested without trans-
mitting the distress signal as follows:
1. Press [F7] to display the Options menu.
2. Press [6] to display the Test menu.
3. Press [4].
4. Press [Enter]. The Distress Alert Button Test mode screen appears.
Options
1. Login
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
3. Self Test
5. Ocean Region
4. Distress Alarm Button Test
6. Test
Figure 6-6 Distress alert button mode screen
5. Open cover on DISTRESS button.
6. Press the DISTRESS button 4 seconds.
7. Confirm that the IC-302 sounds the audible alarm.
8. Close the cover on DISTRESS button.
9. Press any key to escape.
Test
1. PV Test
2. PV Test Result
3. Self Test
4. Distress Alarm Button Test
Figure 6-5 Test Menu
Test
Distress Alert Button Test
Distress alert button test mode.
Press any key to escape.