Cord Sets and Receptacles
Use only high quality, weiHnsuiated, grounded extension
cords with the generator's receptacles. Inspect extension
cords before each use.
Checkthe ratings of all extension cords before you use
them. Extension cord sets used should be rated for AC loads
15 Amps or greater. Check operator's manuals of devices to
be powered for the manufacturer's recommendations.
Keep extension cords as short as possible to minimize
voltage drop.
A WARNING Damagedor overloaded electrical cords
could overheat, arc, and burn resulting in death,
serious injury, and/or property damage.
o ONLYusecordsratedfor your loads.
o Followall safetieson electrical c ords.
o Inspectcordsetsbeforeeachuse.
120 Volt AC, 20 Amp, Duplex Receptacle
The duplex receptacleis protected against overload by an
internal overload system.
Use receptacleto operate 120 Volt AC, single-phase, 60 Hz
electrical loads requiring up to 1,600 watts (1,6 kW) at
13.3 Amps of current. Use cord sets that are rated for
125 Volt AC loads at 15 Amps (or greater).
HOTICE
Receptacles may be marked with rating value
greater than generator output capacity.
o NEVERattempt to power a device requiring more amperage than
generator or receptacle can supply,
o DO NOT overloadthe generator.See Don't OverloadGenerator,
12 Volt DC Receptacle
The maximum current available for the battery charge circuit
is 5 Amps. A DC circuit breaker protects this receptaclefrom
overloads, if an overload occurs, the circuit breaker will trip
(push button pops out). Wait a few minutes and push the
button in to reset the circuit breaker.
This receptacleallows you to recharge a 12 Volt automotive
or utility style storage battery with the battery charge cable
provided.
This receptaclecan not be used to crank an engine having a
discharged battery. See Charging a Battery before attempting
to recharge a battery.
NOTICE When using the batterj charge circuit, turn the
POWERSMARTswitch to the "Off" position.
Output Indicator
The green LED output indicator light comes on when the
generator is operating normally, it indicates that the
generator is producing power at the receptacles.
OUTPUT
OVERLOAD LOW OIL
iNDiCATOR
ALARM
INDICATOR
0verioad Alarm
The red LEDoverload alarm light comes on and cuts power
to the receptacles if you overload the generator. The green
output indicator light will also go off. if the generator was
overloaded, you must turn off and unplug all electrical loads,
shut down the generator and restart it to continue in normal
operating mode.
Low 0ii Indicator
The low oil indicator system is designedto prevent engine
damage caused by not enough engine oil. if the engine oil
level drops below a preset level, the yellow LEDlow oil
indicator light comes on and an oil switch will stop the
engine, if the engine stops or the yellow LED low oil
indicator light comes on when you pull the recoil handle,
check the engine oil level.