Download Print this page
Briggs & Stratton Inverter Generator Quick Setup Manual

Briggs & Stratton Inverter Generator Quick Setup Manual

Hide thumbs Also See for Inverter Generator:

Advertisement

Available languages

Available languages

Quick Links

WARNING Failure to read and follow the
operator's manual and all operating
instructions could result in death or serious
injury.
WARNING Engine exhaust contains carbon
monoxide, a poisonous gas that could kill
you in minutes. You CANNOT smell it, see
it, or taste it. Operate ONLY outside far
away from windows, doors and vents. Install carbon
monoxide alarms. DO NOT run this product inside
homes or garages, even if using fans or opening
doors and windows. Direct exhaust AWAY from
windows, doors, and vents.
WARNING Generator voltage could cause
electrical shock or burn resulting in death
or serious injury. DO NOT operate under
wet conditions.
Items Included (Not Shown):
USB Adapter
Operator's manual
Bottle of engine oil
Screwdriver
Oil Funnel
Items Needed (Not Included):
Carbon monoxide (CO) alarm(s)
Utility knife
Unleaded fuel (minimum 87 octane)
Unpack Generator
1. Set the carton on a rigid, flat surface.
2. Remove everything from carton except generator.
3. Open carton completely by cutting each corner from top to
bottom.
4. Ensure you have all included items prior to assembly.
If items are damaged or missing, call 1-800-743-4115.
Add Engine Oil and Fuel
NOTICE You MUST properly fill engine with oil before
attempting to start generator.
NOTICE DO NOT use unapproved gasoline such as E15 and
E85. DO NOT mix oil in gasoline or modify engine to run on
alternate fuels.
1. Move generator outdoors to a flat, level surface.
2. Loosen the two maintenance cover screws (A) and remove the
side maintenance cover.
1
3. Clean area around oil fill and remove yellow oil fill cap (
4. Using oil funnel, slowly pour contents of provided bottle of
engine oil into oil fill opening to the point of overflowing at oil
fill cap.
3
5. Replace oil fill cap and fully tighten.
6. Replace the maintenance cover and hand tighten the two
maintenance cover screws.
7. Clean area around fuel fill cap (
), remove cap.
8. Slowly add unleaded fuel to red fuel level indicator (B) in fuel
tank. Be careful not to fill above the indicator. This allows
adequate space for fuel expansion.
5
9. Install fuel cap and let any spilled fuel evaporate before
starting engine.
© 2017 Briggs & Stratton Corporation. All rights reserved.
Every effort has been made to ensure that the information in this document is accurate and correct. However, we reserve the right to alter or otherwise improve the product and this document at any time without prior notice and without incurring obligation.
This generator is certified in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-04 (motors and generators) and rated in accordance with PGMA (Portable Generator Manufacturers' Association) standard PGMA G200
(Standard for Testing and Validating Performance of Portable Generators).
Quick Setup Guide
Inverter Generator
WARNING Fuel and its vapors are extremely
flammable and explosive which could
cause burns, fire or explosion resulting
in death or serious injury. Turn generator
engine OFF and let it cool at least 2 minutes before
removing fuel cap. Let spilled fuel evaporate
before starting engine. Always allow space for fuel
expansion.
WARNING Hot exhaust and reflective exhaust
gases could cause burns and fires
resulting in death or serious injury. Keep
at least 5 ft. (1.5 m) clearance from any
combustibles or structures, including overhead.
A
).
2
4
B
Move Generator to
Safe Operating Location
1. Move generator outside to a flat, level surface, in an area
that will not accumulate deadly exhaust gas. Engine exhaust
contains carbon monoxide, a poisonous gas that could kill you
in minutes. You CANNOT smell it, see it, or taste it. Operate
ONLY outside far away from windows, doors and vents. Install
carbon monoxide alarms. DO NOT run this product inside homes
or garages, even if using fans or opening doors and windows.
Direct exhaust AWAY from windows, doors, and vents.
2. To reduce the risk of exhaust heat or exhaust gases igniting
nearby combustible material, keep at least 5 feet (1.5 m)
clearance on all sides of generator, including overhead.
USE OUTDOORS - AVOID CARBON MONOXIDE POISONING
MUFFLER
point away
from home
Start Generator
Disconnect all electrical loads from the generator. Use the
following start instructions.
1. Make sure unit is on a level surface.
NOTICE Failure to start and operate the unit on a level surface
will cause the unit not to start or shut down during operation.
2. Turn the engine switch (D) in ON (I) position.
3. Push choke lever (E) to CHOKE (
NOTICE To help start the engine for the very first time, after
running out of fuel or after a long period of storage, fill fuel tank
as described in Add Fuel. It will require more than several start
attempts until the air in the fuel system has been purged.
4. Grasp recoil handle and pull slowly until slight resistance is
felt. Then pull rapidly to start engine.
5. If engine starts, proceed to step 7. If engine fails to start,
proceed to step 6.
1
6. Move choke lever to half choke position, and pull recoil handle
twice. If engine fails to start, repeat steps 3 thru 4.
7. Slowly move choke lever to RUN (
falters, move choke lever to half choke position until engine
runs smoothly, and then to RUN (
NOTICE If engine starts after 3 pulls but fails to run, or if unit
shuts down during operation, make sure unit is on a level surface
and check for proper oil level in crankcase. This unit may be
equipped with a low oil protection device. If so, oil must be at
proper level for engine to start.
Plug in Items to be Powered
2
1. Make sure the green output indicator light (F) comes on (it
may take up to three seconds).
2. Let engine stabilize and warm up for a few minutes after
starting.
3. Plug in and turn on the desired 120 Volt AC (G), single phase,
60 Hz electrical loads.
WARNING Damaged or overloaded electrical cords could
overheat, arc, and burn resulting in death or serious
injury. ONLY use cords rated for your loads. Follow all
safeties on electrical cords. Inspect cord sets before
each use.
4. If you overload the generator, the red LED overload alarm light
3
(H) comes on and cuts power to the receptacles. The green
output indicator light will also go off. You must turn off and
unplug all electrical loads, press the "Reset" button (J) on the
generator control panel and then plug in and restart electrical
loads one at a time to continue in normal operating mode.
NOTICE DO NOT connect 240 Volt loads to the 120 Volt
receptacles.
NOTICE DO NOT connect 3-phase loads to the generator.
NOTICE DO NOT connect 50 Hz loads to the generator.
FULL OIL
LEVEL
NOTICE DO NOT OVERLOAD THE GENERATOR. Refer to Do
Not Overload Generator section of Operator's Manual.
5. This 12 volt DC receptacle (K) along with the USB adapter
4
allows you to recharge any USB powered device with a USB
charging cable (not included). This receptacle is protected by
a push to reset circuit breaker (L).
Shut Down Generator
1. Turn OFF and unplug all electrical loads from generator
panel receptacles. NEVER start or stop engine with electrical
devices plugged in and turned ON.
2. Let engine run at no-load for several minutes to stabilize
5
internal temperatures of engine and generator.
3. Move engine switch (D) to the OFF (0) position.
4. To prepare for storage, refer to Operator's Manual.
Have Questions?
Do not return to store. We can help.
Call Customer Service Toll-Free 1-800-743-4115
or vist our web site BRIGGSandSTRATTON.COM
6
CARBON MONOXIDE ALARM(S)
Install carbon monoxide alarms inside
your home. Without working carbon
monoxide alarms, you will not realize
you are getting sick and dying from
carbon monoxide poisoning.
7
) position.
8
) position. If engine
) position.
9
9
9
9
7
6
7
D
8
E
9
H
F
G
J
K
L
80014000, Rev A

Advertisement

loading

Summary of Contents for Briggs & Stratton Inverter Generator

  • Page 1 Quick Setup Guide Have Questions? Do not return to store. We can help. Inverter Generator Call Customer Service Toll-Free 1-800-743-4115 or vist our web site BRIGGSandSTRATTON.COM Move Generator to WARNING Failure to read and follow the WARNING Fuel and its vapors are extremely Safe Operating Location operator’s manual and all operating...
  • Page 2 Guía de instalación rápida ¿Tiene Preguntas? No vuelva a la tienda. Podemos ayudarle. Generador tipo inversor Llame gratuitamente al departamento de servicio al cliente, 1-800-743-4115 o visite nuestro sitio web, BRIGGSandSTRATTON.COM Colocación del generador en una ADVERTENCIA Si no se leen y siguen las ADVERTENCIA El combustible y sus vapores posición segura para su uso indicaciones del manual del operario y...