Denso BHT-7500S User Manual page 211

Bar code handy terminal
Table of Contents

Advertisement

Phase 2 with a sequence of DLE EOT and IDs
If the sending station receives a sequence of DLE EOT and IDs anytime during
phase 2, it shifts to phase 3 to terminate the message transmission abnormally.
Even if phase 3 terminates normally, the transmission results in an abnormal end.
Sending
station
Phase 2 with iterated transmission of DLE ENQ and IDs due to no
response or invalid response
If the sending station receives no response or any invalid response from the
receiving station in response to a transmission block sent, it iterates sending of a
sequence of DLE ENQ and IDs at 0.5-second intervals up to 59 times.
If the sending station receives a sequence of DLE ACK and IDs before sending the
sequence of DLE ENQ and IDs 59 times, it continues the subsequent message
transmission.
Sending
station
0.5 second
0.5 second
DLE EOT and IDs
Occurrence of
an error
To phase 3.
Data text m
DLE ENQ and IDs
DLE ENQ and IDs
DLE ACK and IDs
Data text m+1
191
Appendices
Receiving
station
Receiving
station