LX-300+

1.5.3 Bi-Directional Commands

Reply printer ID
Reply printer ID:
[ESC][SOH]@EJL[SP]ID[CR][LF]
The printer sends the following ID string in reply to this command.
Table 1-24.
@EJL[SP]ID[CR][LF]
MFG: EPSON;
CMD: ESCPL2,PRPXL24,BDC;
MDL: LX-300+;
CLS: PRINTER;
DES: EPSON[SP]LX-300+;
[FF]
Enter / Exit Remote Mode
Enter Remote Mode:
Exit Remote Mode:
Remote Commands
Change Printer Settings:
Reply Printer Settings:
XX is a string of 2 ASCII characters of defining a feature of the command.
Following [nL][nH] is two byte hexadecimal value that denotes the length of
the [00H] and [ml]...[mx] parameters. Last [m1] ... [mx] parameters are used to
describe the detailed command function and represent printer settings.
The printer sends the following string in reply to the commands of this type:
@BDC[sp]PS[CR][LF]
XX: Reply-Data;
[FF]
Table 1-25 shows the XXs that are provided in this printer.
Product Description
[ESC](R[08H][00H][00H]REMOTE1
[ESC][NUL][00H][00H]
XX[nL][nH][00H][ml]...[mx]
XX[nL][nH][01H][ml]...[mx]
<Remote commands>
-[Save] column shows that SV commands is effective to each feature or not.
- : All parameters are saved.,
parameter is saved.
Table 1-25. Bi-Directional Commands
Function
Enter Remote-1
Exit Remote-1
Save settings
Initialize
Load power-on default
Select typeface
Select character pitch
Select draft or NLQ
Select character table
Assign character table
Select an international
character set
Turn 1 inch skip
perforation on/off
*1 Don't describe in manual.
*2 m1=0 to 1 only
*3 Only the following parameters are memorized. (Table 1-26)
Control codes
: Some limited parameters are saved.,-: No
Code/ Parameter
ESC"(R"08H 00H 00H "REMOTE1"
ESC 00H 00H 00H
"SV" 00H 00H
"RS" 00H 00H
"LD" 00H 00H
"FO" 02H 00H 00H m1
m1=0(Roman), 1(Sans serif), 5(OCR-B)*1
"CP" 02H 00H 00H m1
m1=0(10cpi), 1(12cpi), 2(15cpi), 3 (17.1cpi),
4(20cpi), 5(Propotional)
"CQ" 02H 00H 00H m1
m1=0(Draft), 1(LQ), 2(High speed draft)
"CT" 02H 00H 00H m1
m1=0 (Table0), 1(Table1)
"AT" 04H 00H 00H m1 m2 m3
m1=0(Table0), 1(Table1)
m2, m3=(ESC/P2 Character Table No.)*4
"IC" 02H 00H 00H m1
m1=0(U.S.A), 1(France), 2(Germany), 3(U.K.)
4(Denmark1), 5(Sweden), 6(Italy), 7(Spain1),
8(Japan), 9(Norway), 10(Denmark2),
11(Spain2), 12(Latin America)
"SK" 02H 00H 00H m1
m1=0(off), 1(on)
Revision A
Save
-
-
-
-
-
∆*2
∆*3
∆*3
∆*5
31