Other Controls - Canon LBP-3260 Service Manual

Hide thumbs Also See for LBP-3260:
Table of Contents

Advertisement

F. Other Controls
1. Main motor control
Figure below shows the main motor control circuit.
DC controller PCB
CPU
IC201
P62
P63
The main motor is a DC brushless motor with hall elements, and is unified with the motor drive
circuit.
The CPU (IC201) sets the MAIN MOTOR DRIVE signal (/MMOTD) to "L" and rotates the main
motor.
When the main motor rotates and reaches its specified speed, it sets the MAIN MOTOR
READY signal (/MMRDY) to "L."
The CPU notifies the video controller PCB of a main motor failure in the following cases:
1) The /MMRDY signal does not become "L" withing 2.5 seconds after from the main motor
rotation starts.
2) The /MMRDY signal becomes "L" once, but becomes "H" for more than 0.1 seconds contin-
uously during the specified speed rotation.
+24VB
J218-5
-6
+5V
-1
38
+5V
-2
39
-3
-4
Figure 2-2-13
Main motor
J36-5
-6
/MMRDY
-1
/MMOTD
-2
-3
-4
CHAPTER 2
MT1
M
2 - 23