5.2.4 Explanation of service data
a) SSSW (Service Soft Switch settings)
The items registered and set by each of these switches comprise 8-bit switches. The figure below shows
which numbers are assigned to which bits. Each bit has a value of either 0 or 1.
SW01
See the chart in the service data shown in this Chapter, 5.2.3 Service data setting to see effective
bits and their default values. The meanings (functions) of the bits are not described in this manual
except the new switches added to this model. See the G3 Facsimile Service Data Handbook
(supplied separately) for details of the switches.
Below are examples showing how to read bit switch tables.
Bit
Function
0
Service error code
1
Error dump list
2
Not used
3
Copy function
4
##300 series service error code
5
Not used
6
Not used
7
User setting restriction
Figure 4-21 How to Read Bit Switch Tables
0
0
0
0
Figure 4-20 Bit Switch Display
Indicates that the
setting is "1".
1
Output
Output
No
Output
Setting possible
4-41
0
0
0
0
Indicates that the
setting is "0".
Figures in boldface
are default settings.
0
Not Output
Not Output
Yes
Not Output
Setting restricted