Canon SmartBase MPC400 Service Manual page 103

Hide thumbs Also See for SmartBase MPC400:
Table of Contents

Advertisement

SmartBase MPC600F/MPC400 Chapter 4: Maintenance & Service
c) ERROR CODE LIST
The error codes that have newly been added starting with the product are identified by the notation
" new " those error codes for which remedies unique to the product are offered are identified by the
notation "UNQ (UNIQUE)."
C-1) User error code
No.
Tx or Rx
#001
[ TX
]
#003
[ TX/RX ]
#005
[ TX/RX ]
#009
[ RX
]
#012
[ TX
]
#018
[ TX/RX ]
#022
[ TX
]
#037
[ RX
]
#052
[ RX
]
#085
[ TX
]
#995
[ TX/RX ]
c-2) Service error code
• G3 mode error codes
No.
Tx or Rx
##100
[ TX
]
##101
[ TX/RX ]
##102
[ TX
]
##103
[ RX
]
##104
[ TX
]
##106
[ RX
]
##107
[ RX
]
##109
[ TX
]
##111
[ TX/RX ]
##114
[ RX
]
##200
[ RX
]
##201
[ TX/RX ]
##204
[ TX
]
##220
[ TX/RX ]
##224
[ TX/RX ]
##229
[ RX
]
##232
[ TX
]
##237
[ RX
]
##238
[ RX
]
##261
[ TX/RX ]
##280
[ TX
]
##281
[ TX
]
##282
[ TX
]
Definition
Paper jam
Copy page, communication time over
Initial ID (T1) time over
Recording paper jam or out of paper
Other party out of paper
Automatic dialing error
Call failure
Image memory full
Image memory full by no ink error
Other party does not support ITU-T Color Faxing
Memory Communication reservation cancellation
Definition
Excessive repeat protocol during Rx
Modem speed different from other party
Fall back failure during Tx
Fail to detect EOL for 5 seconds (15 seconds for CBT) during
Rx
RTN or PIN received during Tx
Fail to receive protocol for 6 seconds when waiting for
protocol during Rx
Fall back failure on Tx side during Rx
Receive Signals other than DIS, DTC, FTT, CFR or CRP after DCS
Tx and exceed the number of protocol re-transmissions during Tx
Memory error
RTN Transmission during reception
Fail to detect picture Rx carrier for 5 seconds during Rx
DCN received other than normal binary protocol
Receive DTC without Tx data
System error (main program runaway)
Abnormal protocol during G3 communication
Recording unit locked for 1 minute
ENCODE control unit malfunction
DECODE control unit malfunction
PRINT control unit malfunction
System error between MODEM and SCNT
Excessive repeat protocol command during Tx
Excessive repeat protocol command during Tx
Excessive repeat protocol during Tx
4-19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartbase mpc600f

Table of Contents