Error Message and Recovery Procedures

Environment Messages

Catalyst 2900 Series XL and Catalyst 3500 Series XL Software Configuration Guide
A-6
CMP-5-REMOVE The Device is removed from the cluster (Cluster
Name:[chars])
The message means that the device is removed from the cluster:
Explanation
[chars] is the cluster name.
No action is required.
Action
This section contains the Environment error messages.
ENVIRONMENT-2-FAN_FAULT
This message means that an internal fan fault is detected. This
Explanation
message is available only on the Catalyst 3524-PWR XL switch.
Either check the switch itself, or use the show env privileged EXEC
Action
command to check if a fan on the switch has failed. The
Catalyst 3524-PWR XL switch can operate normally with one failed fan.
Replace the switch at your convenience.
ENVIRONMENT-2-OVER_TEMP
This message means that an overtemperature condition is
Explanation
detected. This message is available only on the Catalyst 3524-PWR XL
switch.
Action
Use the show env command to check if an overtemperature condition
exists. If it does:
Place the switch in an environment that is within 32 to 113°F (0 to 45°C).
Make sure fan intake and exhaust areas are clear.
If a multiple-fan failure is causing the switch to overheat, replace the switch.