A.3 Standalone Commands
Use the following commands, in the order they are listed, to configure the NetAXS™
panel.
1. T command: Sets the panel's Time
2. D command: Sets the panel's Date
3. L command: Creates Time zones for use by the cards
4. C command: Adds or Deletes cards from the panel
5. W command: Program each input for either NO/NC and Supervised or NON
6. P command: Sets interlocks between input points and/or output points
In all examples, the underbar "_" indicates a "space" character and <CR>
Note:
indicates a carriage return.
A.3.1 T (Time) Command
_T=pn_hh:mm<CR>
Variables:
pn = panel number (1-31)
hh = hours (0-23) (Military time)
mm = minutes (00-59)
Example #1:
_T=1_08:30<CR>
This command would set panel 1 to a time of 8:30 AM.
Example #2
_T=6_18:15<CR>
This command would set panel 6 to a time of 6:15 PM.