Netaxs™ Access Control Unit; Real-Time Clock Protection; Memory Protection; Reader And Aux Power - Honeywell NetAXS NX4S1 Installation Manual

Access control unit
Table of Contents

Advertisement

Maintain at least a .25-inch distance between the non-power limited wiring
Note:
battery backup/charger wiring) and all other wiring, which is power-limited
Class 2 wiring.
3.1 NetAXS™ Access Control Unit
The NetAXS™ panel is a four-reader board that controls up to four doors by
providing up to 14 inputs and 8 outputs. The NetAXS™ panel may be used as a
stand-alone panel with independent card and transaction storage or, with a host
software upgrade, as a fully monitored online access control device. The NetAXS™
panel also supports up to 30 downstream panels in a variety of network
configurations. See Communications, page 16, for descriptions and illustrations.
Fourteen inputs are capable of four state supervision: Normal, Alarm, Short and Open.
Eight inputs are used as door control with one input used for request to exit on each
door and one input used for door status on each door. Supervised inputs for Tamper,
External Power Fail and four Reader Tampers are supplied as well, and they can be
used as additional inputs when not required for their default purpose.
Caution:
relay board can the common power supply be used for the NetAXS™ and locking
devices.

Real-Time Clock Protection

The panel RTC is backed up using a super capacitor. The super capacitor will power
the real-time clock for one week in the absence of primary power or backup battery.

Memory Protection

The NetAXS™ panel continuously saves database and event information in
non-volatile FLASH memory. This activity prevents the panel from losing data when
power is lost.

Reader and AUX Power

Reader power is supplied within the range of 11.2 VDC and 12.4 VDC with a
maximum current of 600 mA. AUX power is supplied within the range of 10.5 VDC
and 12.4 VDC with a maximum current of 500mA. The current can be distributed
throughout the Reader Power or AUX Power in any configuration as long as the
maximum draw is less than 600 mA: Reader 1 + Reader 2 + Reader 3 + Reader 4 +
AUX Power < 600 mA.
Caution:
For NetAXS™ maximum current draw, refer to
NetAXS Access Control Unit NX4S1 Installation Guide, Document 800-00008, Revision A
The NetAXS™ board must not be used to power locks. Only through the