Table D-4: Is the Internal Health LED Green?

Answer
Possible Reasons
No, it is
A processor or DIMM is in pre-failure
amber
condition.
No, it is
A processor, PPM, or fan has failed.
red
Processor 1 is not installed.
A processor is an unsupported type.
Processors are mismatched (speed
and/or type).
A DIMM has experienced a multibit error.
No valid memory is in the system.
The SCSI cabling or terminator
configuration is incorrect on the SCSI
controller.
An overtemperature condition has
occurred.
Yes
If the internal health LED is green, refer to Table D-5.
HP ProLiant ML330 Generation 3 Server Setup and Installation Guide
Server Specific Troubleshooting
Possible Solutions
Use amber failure LEDs to identify:
Missing components
Degraded components
Failed components
Improperly installed components
Contact the authorized service provider
for replacement parts and service.
Use amber failure LEDs to identify:
Missing components
Degraded components
Failed components
Improperly installed components
Contact the authorized service provider
for replacement parts and service.