Table D-2: Is the System Power LED Amber?

Answer
Possible Reasons
No
The server is not connected to AC power
or no AC power is available.
The power supply may not be inserted
properly, it may have a damaged
connector, or it may have failed.
A broken connection exists between the
following:
Power supply and system board
System board and power button/LED
assembly
The power supply, system board,
and/or power button/LED assembly
may need to be replaced.
Yes
If the system power LED is amber:
1.
Press the Power On/Standby button.
2.
Refer to Table D-3.
HP ProLiant ML330 Generation 3 Server Setup and Installation Guide
Server Specific Troubleshooting
Possible Solutions
Be sure that the power cord is connected
to the power supply.
Be sure that the power supply is
undamaged and is fully seated.
Be sure that the power supply cables are
connected to the system board.
Be sure that the power button/LED cable
is connected to the system board and
power button/LED assembly.
Be sure that all pins on connectors and
components are straight.
Refer to the Servers Troubleshooting
Guide for further options regarding power
and general hardware problems.
Contact the authorized service provider
for assistance.