■ Connections (IS-SS)
*1
Electric door strike
φ0.65-1.2mm
(22-16 AWG)
10m (33')
Connect to the electric
*
door strike according to its
specifi cations.
*1: Output specifi cations
Output method
Voltage between
terminals
NOTES:
Do not use the unoccupied terminals and ports for other purposes.
•
In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.
•
For connecting other manufacture's products, refer to the instruction manuals for those products.
•
The illustration of the unit's rear panel differs from the actual one. This is for simplifying the connection diagram.
•
D
φ0.65-1.2mm
(22-16 AWG)
10m (33')
AC transformer
PT
φ0.65-1.2mm
(22-16 AWG)
10m (33')
Option
Inlet
wires
Terminal cover
CAT5e/6 cable
N/O or N/C dry closure contact
24V AC, 0.5A (resistive load)
24V DC, 0.5A (resistive load)
Minimum overload (AC/DC):
100mV, 0.1mA
CAT5e/6
(non-shielded)
D1
D4
300m (980')
(Select one port.)
or
CAT5e/6
(non-shielded)
D8
D1
300m (980')
(Select one port.)
or
CAT5e/6
(non-shielded)
C1
C30
(Select one port.)
300m (980')
The terminals are inside the terminal
*
cover. After connecting, route the
wires through the wiring paths, then
close the cover.
Be sure to route the CAT5e/6 cable
*
and option wires through inlet.
When closing the terminal cover,
*
close it until it clicks.
Central control unit
(IS-CCU)
Add-on control unit
(IS-SCU)
Room sub control unit
(IS-RCU)
23