■ Connections

PA output
(50mVrms, 600Ω)
PA amplifi er
*1
NP
NP
2C
2C
φ0.65-1.2mm
φ0.65-1.2mm
(22-16 AWG)
(22-16 AWG)
15m (50')
P1
P2
P3
P4
PA OUTPUT (600Ω)
MASTER STATION
M1
M3
M2
M4
CAT5e/6
(non-shielded)
300m
(980')
M
Master station
(IS-MV)
*1: This connection is needed when a PA amplifi er that needs a trigger input is connected. (Up to AC/DC 24V 0.5A)
*2: Do not install two power supplies in parallel to a single input. Be sure to connect a single power supply unit to a control unit.
*3: Setting the ID setting switch
ID No.
Switch position
ON
ID 1
OFF
ON
ID 2
OFF
*4: Refer to "Output specifi cations" (→P.11).
NOTES:
Do not use the unoccupied terminals and ports for other purposes.
In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.
For connecting other manufacturer's products, refer to the instruction manuals for those products.
The illustration of the unit's front panel differs from the actual one. This is for simplifying the connection diagram.
*4
Contact output
(Electric door strike, strobe light, etc.)
NP
2C
φ0.65-1.2mm
(22-16 AWG)
AC
transformer
PT
L1
L2
L3
CONTACT OUTPUT (AC/DC24V 0.5A)
VIDEO/AUDIO DOOR/SUB STATION
M5
M7
D1
M6
M8
D2
CAT5e/6
(non-shielded)
(non-shielded)
300m
(980')
or
D
Door station
Room sub station
(IS-DV/IS-DVF/
(IS-RS)
IS-SS)
Set to this position when this unit is connected to 1MX1, 1MX2 and 1MX3 ports of IS-CCU.
Set to this position when this unit is connected to 2MX1, 2MX2 and 2MX3 ports of IS-CCU.
L4
D3
D5
D7
D4
D6
D8
CAT5e/6
150m
(490')
C
1MX1 1MX2 1MX3
Central control unit
(IS-CCU)
Description
Monitor 1,
Monitor 2,
Recorder 1
Recorder 2
BNC
BNC
connector
connector
Coax
Coax
15m (50')
15m (50')
NTSC
NTSC
BNC
BNC
connector
connector
V1
V2
VIDEO OUTPUT
IS-CCU
MX1
MX3
1
ID
2
MX2
*3
ID setting switch
CAT5e/6 (x3)
(non-shielded)
200m
(650')
NP: Non-polarized
P: Polarized
DC48V
P
2C
φ0.8-1.2mm
(20-16 AWG)
15m(50')
*2
Power supply unit
(IS-PU-UL/IS-PU-S)