Connections - Aiphone IS SERIES Installation Manual

Commercial & security video intercom system
Hide thumbs Also See for IS SERIES:
Table of Contents

Advertisement

■ Connections

PA output
(50mVrms, 600Ω)
PA amplifi er
*1
NP
NP
2C
2C
φ0.65-1.2mm
φ0.65-1.2mm
(22-16 AWG)
(22-16 AWG)
15m (50')
AC
transformer
NP: Non-polarized
P: Polarized
P1
P2
P3
PA OUTPUT (600Ω)
IS-RCU
1CX1
2CX1
3CX1
1CX2
2CX2
3CX2
CAT5e/6
CAT5e/6
(non-shielded)
(non-shielded)
200m
200m
(650')
(650')
CX1/IP1
CX2/IP2
Room sub control unit
(IS-RCU)
*1: This connection is needed when a PA amplifi er that needs a trigger input is connected. (Up to AC/DC 24V 0.5A)
*2: This connection is needed when a sound source etc. that needs a trigger input is connected. (Up to AC/DC 24V 0.5A) Connect a timer to the
CONTACT INPUT terminals when an external sound source device (CD player etc.) that does not have a timer function is connected.
*3: This connection is needed when a sound source that has a trigger output is connected.
*4: Refer to the SETTING MANUAL for connection and settings.
*5: Do not install two power supplies in parallel to a single input. Be sure to connect a single power supply unit to a control unit.
*6: Do not use an external sound source as background music. If the background music is interrupted by another performance during chime paging,
the chime paging will not be restored after the performance ends.
*7: Outputs images only from a video door station connected to this unit.
*8: Output specifi cations
Output method
N/O or N/C dry closure contact
Voltage between
24V AC, 0.5A (resistive load)
24V DC, 0.5A (resistive load)
terminals
Minimum overload (AC/DC): 100mV, 0.1mA
NOTES:
Do not use the unoccupied terminals and ports for other purposes.
In order to prevent miswiring, label both ends of each cable with
the unit and terminal names to which they are to be connected.
For connecting other manufacturer's products, refer to the
instruction manuals for those products.
The illustration of the unit's front panel differs from the actual
one. This is for simplifying the connection diagram.
*8
Contact output
(Electric door strike, strobe light, etc.)
NP
2C
φ0.65-1.2mm
(22-16 AWG)
PT
P4
L1
L2
L3
L4
L5
L6
CONTACT OUTPUT (AC/DC24V 0.5A)
MASTER STATION
4CX1
M1
M3
4CX2
M2
M4
CAT5e/6
CAT5e/6
(non-shielded)
(non-shielded)
300m
150m
(980')
(490')
M
C
Master station
Room sub station
(IS-MV)
(IS-RS)
Chime input (50mVrms, 600Ω)
External sound
Contact input
*9
source such as
Sensor, etc.
CD player, etc.
*2
*3
NP
P
2C
2C
φ0.65-1.2mm
φ0.65-1.2mm
(22-16 AWG)
(22-16 AWG)
15m (50')
P
2C
φ0.65-1.2mm
(22-16 AWG)
15m (50')
L7
L8
S1 E S2 E S3 E S4 E
CONTACT INPUT
VIDEO/AUDIO
DOOR/SUB STATION
IS-SCU
D1
D3
1MX1
1MX3
D2
D4
1MX2
2MX1
CAT5e/6
(non-shielded)
300m
(980')
or
D
MX1 MX2 MX3
Add-on control unit
Door station
(IS-SCU)
(IS-DV/IS-DVF/
IS-SS)
*9: Input specifi cations
Input method
Detection confi rmation
time
Contact resistance
Terminal short current
Voltage between
terminals
*7
*7
Monitor 1,
Monitor 2,
*6
Recorder 1
Recorder 2
BNC
BNC
NP
connector
connector
2C
φ0.65-1.2mm
(22-16 AWG)
15m (50')
Coax
Coax
15m (50')
15m (50')
NTSC
NTSC
BNC
BNC
connector
connector
B1
B2
V1
V2
CHIME INPUT (600Ω)
VIDEO OUTPUT
IS-IPC
2MX2
IP1
2MX3
IP2
IP3
CAT5e/6 (x3)
CAT5e/6 (x3)
(non-shielded)
(non-shielded)
200m
10m (33')
(650')
IP1
IP2
IP3
IP control unit
(IS-IPC)
N/O or N/C dry closure contact (start
signal only detection method)
100 ms or more
During N/O dry closure: Less than 700 Ω
During N/C dry closure: At least 4 k Ω
Less than 10 mA
Less than 5 V DC (when open between
terminals)
PC for setting
the system
*4
LAN
ETHERNET
DC48V
2C
φ0.8-1.2mm
(20-16 AWG)
P
15m
(50')
*5
Power supply unit
(IS-PU-UL/IS-PU-S)
11