Troubleshooting Using Raid Manager - HP StorageWorks P9000 User Manual

Continuous access synchronous user guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Troubleshooting using RAID Manager

When an error occurs in pair operations using RAID Manager, you can identify the cause of the
error by referring to the RAID Manager operation log file. This file is stored in the following directory
by default:
/HORCM/log*/curlog/horcmlog_HOST/horcm.log
Where:
* is the instance number.
HOST is the host name.
Example:
Error codes appear on the right of the equal symbol (=).
Investigate the description of the error code using
Contact your HP representative for the error code that has not been described in the table.
Table 27 RAID Manager error codes for Continuous Access Synchronous (SSB1 is
B901/B90A/B90B/B912/D004)
Error code
Description
(SSB2)
4A96
A request for a Paircreate operation was received. The command was rejected because the specified P-VOL
belongs to a different CLPR than the registered consistency group CLPR.
B927
You cannot execute the following operations to a pair in a 2DC configuration:
Swap Suspend
Takeover
B928
The pair cannot be created because the Mirror ID is invalid.
B929
The pair operation was rejected because the online microcode is being replaced.
B92A
The pair cannot be created because the specified volume is a command device.
B934
The pair cannot be created because Continuous Access Synchronous is not installed.
B935
S-VOL hide mode is not supported.
B93B
The specified volume is a P-VOL. The pair cannot be released because the P-VOL is specified as an S-VOL.
B941
The specified volume is an S-VOL. The pair cannot be released because the S-VOL is specified as an P-VOL.
B945
The command was rejected because the volume status is SMPL.
B952
The specified LU is not defined. The DKC configuration might have been changed. Restart RAID Manager.
B97B
The operation cannot be executed because pair status is PSUS, PSUE, or PDUB.
B97C
The command was rejected because the volume status is SMPL.
B990
The pair cannot be created because the consistency group number is greater than is allowed.
If this error occurred when you did not specify the consistency group number, contact HP Technical Support.
B994
The Swap Resync operation cannot be performed because the S-VOL is not in PSUS or SSWS status (Swap
Resync resynchronizes differential data when the S-VOL is swapped for the P-VOL).
B998
The pair cannot be created because the remote system path setting in Remote Web Console is invalid.
B99B
The pair cannot be created because Continuous Access Asynchronous is not supported.
Table 27 (page 73)
or
Troubleshooting using RAID Manager
Table 28 (page
80).
73

Advertisement

Table of Contents
loading

Table of Contents