HP StorageWorks P9000 User Manual page 71

Continuous access synchronous user guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 25 Troubleshooting secondary path status problems (continued)
Path status
Description
Invalid Port Mode
The specified port is not
configured as an initiator port
or this path already exists.
Port number invalid
The specified port number is
invalid. The cable is not
connected to the specified
port.
Fibre remote copy is
The microcode on the remote
not supported.
system does not support the
fibre remote copy function.
Communication error
A timeout error has occurred
between the primary and
secondary systems.
RCU Port Number
The specified port in the
Mismatch
secondary system is
physically disconnected from
the primary system.
RCU Port Type
The specified remote system
Mismatch
port is not configured as an
RCU target port.
Communication Failed
The primary system connected
to the remote system
successfully, but logical
communication timeout
occurred.
Logical Blockade
The primary system port does
not work.
secondary system port does
not work.
The path relay equipment
does not work.
The connection cable is
physically broken.
Program Error
A program error is detected.
Corrective action
Make sure the correct primary system port is configured as
an initiator port and the correct secondary system port is
configured as an RCU target port.
Make sure that you entered the correct secondary system
S/N, SSID, and path parameters (port, link address, logical
address).
Delete the failed path. You may need to change the
minimum paths setting or delete the secondary system in
order to delete the path. Then add the path/secondary
system using Edit Path or Add RCU.
Delete the failed path. Check the port number or the cable
connection and retry.
Install the microcode that supports the fibre remote copy
function on the remote system.
Delete the failed path and retry.
Make sure that you entered the correct secondary system
port number. Correct the port number if necessary.
Make sure that the primary and secondary systems are
physically connected.
Make sure that the Fibre Channel topology settings of the
primary and secondary systems ports are correct.
Make sure that the secondary system port is configured as an
RCU target port. See
"Define port attributes" (page
Make sure that the secondary system port and data path
hardware (cables and switches) are properly configured and
functioning.
Repair the port on the primary system.
Repair the port on the secondary system. Delete the path with
Edit Path or Delete RCU, then add the path again with Edit
Path or Add RCU.
Repair the path relay equipment. Delete the path with Edit Path
or Delete RCU, then add the path again with Edit Path or Add
RCU.
Replace the broken cable. Delete the path with Edit Path or
Delete RCU, then add the path again with Edit Path or Add
RCU.
Delete the path with Edit Path or Delete RCU, then add the
path again with Edit Path or Add RCU.
37).
General troubleshooting