Delete Logical Paths - HP StorageWorks P9000 User Manual

Continuous access synchronous user guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 22 Logical path status definitions (continued)
Status
Path Rejected
Serial Number Mismatch
Invalid Port Mode
RCU Port Number
Mismatch
RCU Port Type Mismatch
Communication Failed
Logical Blockade
Program Error
In Progress

Delete logical paths

You can delete a logical path from to a secondary system.
Prerequisite information
Delete logical paths from the primary system.
Make sure that the remaining number of paths is equal to or greater than the minimum number
of paths setting on the RCU Option dialog box, otherwise the delete path operation will fail.
Procedure 14 To delete a logical path
1.
On the menu bar, click Actions > Remote Copy > Continuous Access Synchronous > RCU
Operation. The RCU Operation window opens.
2.
Change to Modify mode by clicking the
3.
In the RCU Operation window, click MCU&RCU. The tree and list on the right-side display
information about secondary system.
4.
In the tree, select the local system then select the desired secondary system (RCU). Alternatively,
select the RCU in the list, right click and click Edit SSID(s) & Path(s). All paths to the selected
RCU are listed.
5.
Right-click the path(s) that you want to delete, and then click Delete Path. When the confirmation
message appears, click OK to delete the path(s), or click Cancel to cancel your request. The
preview list displays the path(s) that you want to delete. Delete is displayed on the rightmost
column of the selected path in the SSID/Path list.
6.
Verify the requested operation(s) displayed in the preview list and the SSID/Path list. To remove
an operation, select the operation, right-click, and the click Delete.
To cancel all operations, select all the operations in the preview list, right click, and click the
Delete command, or click Cancel.
7.
When satisfied, click Apply. This saves the configuration to the Continuous Access Synchronous
system.
Description
The logical path link function has been rejected by the secondary system. All logical path
resources in the secondary system might be used for other connections.
The serial number of the control unit that is connected to this logical path does not match
the serial number specified by the Add RCU dialog box.
The specified port does not have the initiator attribute.
There are three possible causes:
The specified port in the secondary system is physically disconnected from the primary
system.
The port is not configured as an RCU target port.
The specified port number is not available.
The microcode on the secondary side does not support the fibre remote copy function, or
the specified port type is not RCU target.
A timeout error has occurred on the path between the primary and secondary systems.
This logical path was blockaded because a path error or a link error occurred continuously.
This logical path was blockaded because a program error occurred.
This logical path is in progress of changing the attribute of port.
icon.
Monitor, maintain logical paths
59