The switch software supports SNMP-based network management. In SNMP model of network manage-
ment, a management station (client/manager) accesses a set of variables known as MIBs (Management
Information Base) provided by the managed device (agent). If you are running an SNMP network
management station on your network, you can manage the switch using the following standard SNMP
MIBs:
MIB II (RFC 1213)
Ethernet MIB (RFC 1643)
Bridge MIB (RFC 1493)
An SNMP agent is a software process on the managed device that listens on UDP port 161 for SNMP
messages. Each SNMP message sent to the agent contains a list of management objects to retrieve or to
modify.
SNMP parameters that can be modified include:
System name
System location
System contact
Use of the SNMP system authentication trap function
Read community string
Write community string
The following table describes the System SNMP Configuration Menu options.
Table 84
System SNMP Configuration Menu options
Command
snmpv3
name <1-64 characters>
locn <1-64 characters>
cont <1-64 characters>
rcomm <1-32 characters>
wcomm <1-32 characters>
timeout <1-30>
auth disable|enable
linkt <port>
[disable|enable]
ufd
Description
Displays SNMPv3 menu.
Configures the name for the system. The name can have a maximum of 64
characters.
Configures the name of the system location. The location can have a maximum
of 64 characters.
Configures the name of the system contact. The contact can have a maximum of
64 characters.
Configures the SNMP read community string. The read community string
controls SNMP "get" access to the switch. It can have a maximum of 32
characters. The default read community string is public.
Configures the SNMP write community string. The write community string
controls SNMP "set" and "get" access to the switch. It can have a maximum of
32 characters. The default write community string is private.
Sets the timeout value for the SNMP state machine. The range is 1-30 minutes.
The default value is 5 minutes.
Enables or disables the use of the system authentication trap facility. The default
setting is disabled.
Enables or disables the sending of SNMP link up and link down traps. The
default setting is enabled.
Enables or disables the sending of Uplink Failure Detection traps. The default
setting is disabled.