Statement 2:
CAUTION:
When replacing the lithium battery, use only IBM Part Number 33F8354 or an
equivalent type battery recommended by the manufacturer. If your system has
a module containing a lithium battery, replace it only with the same module
type made by the same manufacturer. The battery contains lithium and can
explode if not properly used, handled, or disposed of.
Do not:
v Throw or immerse into water
v Heat to more than 100°C (212°F)
v Repair or disassemble
To install the battery, complete the following steps:
1. Follow any special handling and installation instructions that come with the
2. Insert the new battery:
3. Install the side cover (see "Installing the side cover" on page 53).
4. Lock the side cover if you unlocked it during removal.
5. Reconnect the external cables and power cords; then, turn on the attached
6. Start the Configuration/Setup Utility program and reset the configuration:
78
System x3200 M2 Types 4367 and 4368: Problem Determination and Service Guide
replacement battery.
a. Tilt the battery so that you can insert it into the socket on the side opposite
the battery clip.
b. Press the battery down into the socket until it clicks into place. Make sure
that the battery clip holds the battery securely.
devices and turn on the server.
v Set the system date and time.
v Set the power-on password.
v Reconfigure the server.
See "Using the Configuration/Setup Utility program" on page 16 for details.