v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, System x3200 M2 Types 4367 and 4368," on page 33 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
1805
PCI option ROM checksum error.
1806
PCI built in self-test failure.
1807
General PCI error.
Action
1. Remove the failing adapter.
2. Reseat each adapter.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Failing PCI or PCI Express adapter
b. (Trained service technician only) System
board
1. If the error code indicates a particular PCI or
PCI-Express slot or device, remove that device.
2. Reseat the following components:
a. Each adapter
b. (Trained service technician only, if the
specified board is a FRU) The board that is
indicated in the error code. (See Chapter 3,
"Parts listing, System x3200 M2 Types 4367
and 4368," on page 33 to determine CRU or
FRU status.)
3. Replace the components listed in step 2 one at a
time, in the order shown, restarting the server
each time.
1. Make sure that no devices have been disabled in
the Configuration/Setup Utility program.
2. Replace each adapter one at a time, restarting
the server each time.
133