IBM 436854u - System x3200 M2 5U Mini Tower Server Problem Determination And Service Manual page 228

Service guide
Hide thumbs Also See for 436854u - System x3200 M2 5U Mini Tower Server:
Table of Contents

Advertisement

Table 9. DSA diagnostic messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 3, "Parts listing, System x3200 M2 Types 4367 and 4368," on page 33 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained
service technician.
Message
number
Component
215-903-xxx
Optical drive
210
System x3200 M2 Types 4367 and 4368: Problem Determination and Service Guide
Test
State
Self-Test
Aborted
Description
Action
Could not access
1. Insert a new CD or DVD into the drive
the drive.
and wait for 15 seconds for the media
to be recognized.
2. Run the test again.
3. Check the drive cabling for loose or
broken connections at both ends or
damage to the cable. Replace the
cable if it is damaged.
4. Run the test again.
5. Make sure that the DSA code is at the
latest level. For the latest level of DSA
code, go to http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
DSA.
6. Run the test again.
7. For additional troubleshooting
information, see the "Troubleshooting
CD and DVD drive issues" site at
http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-41559.
8. Run the test again.
9. Replace the optical drive.
10. Run the test again.
11. If the problem remains, collect the
data from the DSA event log and send
it to IBM Service. For information
about contacting and sending data to
IBM Service, see
http://www.ibm.com/support/
docview.wss?uid=psg1SERV-CALL.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

X3200 m2X3200 m2 436843674368X3200 m2 type 4367X3200 m2 type 4368

Table of Contents