IBM 436854u - System x3200 M2 5U Mini Tower Server Problem Determination And Service Manual page 146

Service guide
Hide thumbs Also See for 436854u - System x3200 M2 5U Mini Tower Server:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, System x3200 M2 Types 4367 and 4368," on page 33 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
162
Invalid configuration information or CMOS
random-access memory (RAM) checksum
failure.
163
Time of day not set.
164
Memory size has changed.
128
System x3200 M2 Types 4367 and 4368: Problem Determination and Service Guide
Action
1. Run the Configuration/Setup Utility program,
select Load Default Settings, and save the
settings.
2. Reseat the following components:
a. Battery
b. Failing device (if the device is a FRU, the
device must be reseated by a trained service
technician only)
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. Failing device (if the device is a FRU, the
device must be replaced by a trained service
technician only)
c. (Trained service technician only) System
board
1. Run the Configuration/Setup Utility program,
select Load Default Settings, make sure that the
date and time are correct, and save the settings.
2. Reseat the battery.
3. Clear CMOS. See "System-board jumpers" on
page 13 for information about how to clear
CMOS.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. (Trained service technician only) System
board
1. Run the Configuration/Setup Utility program,
select Load Default Settings, make sure that the
date and time are correct, and save the settings.
2. Reseat the battery.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. (Trained service technician only) System
board

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

X3200 m2X3200 m2 436843674368X3200 m2 type 4367X3200 m2 type 4368

Table of Contents