on page 9 for the location of this connector on the system board. After you install
the Remote Supervisor Adapter II SlimLine, the systems-management Ethernet port
on the rear of the server is active.
To install a Remote Supervisor Adapter II SlimLine, complete the following steps:
1. Read the safety information beginning on page vii, and "Installation guidelines"
on page 47.
2. Turn off the server and peripheral devices, and disconnect the power cords
and all external cables.
3. Lay the server on its side.
4. Unlock the side cover.
5. Remove the side cover (see "Removing the side cover" on page 52.
6. Open the rear adapter-retention bracket and install the Remote Supervisor
Adapter II SlimLine retention tab on the bracket by clipping it onto the rear
adapter-retention bracket.
Adapter retention bracket
Remote Supervisor Adapter II
SlimLine retention tab
7. Carefully grasp the Remote Supervisor Adapter II SlimLine by its top edge or
upper corners, and align it with the Remote Supervisor Adapter II SlimLine
guide and the connector on the system board.
Attention:
Incomplete insertion might cause damage to the system board or
the adapter.
Chapter 4. Removing and replacing server components