v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, System x3200 M2 Types 4367 and 4368," on page 33 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Beep code
1-2-4
1-3-1
2-1-1
2-1-2
2-1-3
2-1-4
2-3-4
3-3-2
Description
RAM refresh verification failed.
First 64 K RAM test failed.
Secondary DMA register failed.
Primary DMA register failed.
Primary interrupt mask register failed.
Secondary interrupt mask register failed. (Trained service technician only) Replace the
Search for video ROM failed.
Critical SMBUS error occurred.
Action
1. Reseat the DIMMs.
2. Replace the following components one at a
time, in the order shown, restarting the
server each time:
a. DIMMs
b. (Trained service technician only) System
board
1. Reseat the DIMMs.
2. Clear CMOS. See "System-board jumpers"
on page 13 for information about how to
clear CMOS.
3. Replace the following components one at a
time, in the order shown, restarting the
server each time:
a. DIMMs
b. (Trained service technician only) System
board
(Trained service technician only) Replace the
system board.
(Trained service technician only) Replace the
system board.
(Trained service technician only) Replace the
system board.
system board.
(Trained service technician only) Replace the
system board.
1. Disconnect the power cord, wait 30
seconds, and retry.
2. Reseat the following components:
a. DIMM
b. System board
3. Replace the following components one at a
time, in the order shown, restarting the
server each time:
a. DIMM
b. (Trained service technician only) System
board
Chapter 5. Diagnostics
123