To remove a non-hot-swap power supply, complete the following steps:
1. Read the safety information that begins on page vii and "Installation guidelines"
2. Turn off the server and all attached devices; then, disconnect all power cords
3. Unlock and remove the side cover (see "Removing the side cover" on page 52).
4. Disconnect the cables from the power supply to the system board and all
5. While you support the power supply, remove the four screws that secure it to
6. If you are instructed to return the power supply, follow all packaging instructions,
106
System x3200 M2 Types 4367 and 4368: Problem Determination and Service Guide
on page 47.
and external cables.
Note: It might be helpful to lay the server on its side for the remainder of this
procedure.
internal components.
Attention:
Support the power supply while you remove the mounting screws.
After the screws are removed, the power supply is loose and can damage other
components in the server.
the chassis; then, lift the power supply out of the chassis. Save the screws to
use when you install the replacement power supply.
and use any packaging materials for shipping that are supplied to you.