SCSI error codes
Error code
All SCSI Errors One or more of the
following might be causing the problem:
v A failing SCSI device
(adapter, drive)
v An improper SCSI configuration
v Duplicate SCSI IDs in the same SCSI
chain
Temperature error messages
Note: See Chapter 7, "Parts listing, Type 8839," on page 105 to determine which components should be replaced by
a field service technician.
Message
System over temperature for CPU x.
Blade Storage Expansion option over
recommended temperature.
CPU x over temperature.
Power error messages
Note: See Chapter 7, "Parts listing, Type 8839," on page 105 to determine which components should be replaced by
a field service technician.
Message
BSE +12V over recommended voltage
BSE +12V under recommended voltage
BSE +5V over recommended voltage
FRU/action
Make sure that the SCSI devices are configured correctly.
Action
1. Ensure that the system is being properly cooled; see "System
reliability considerations" on page 33.
2. Replace microprocessor x.
1. Ensure that the system is being properly cooled; see "System
reliability considerations" on page 33.
2. Replace the SCSI hard disk drives.
3. Replace the Blade Storage Expansion option.
1. Ensure that the system is being properly cooled; see "System
reliability considerations" on page 33.
2. Replace microprocessor x.
Action
1. Check BladeCenter power (see IBM BladeCenter Type 8677
Hardware Maintenance Manual and Troubleshooting Guide).
2. Reseat blade storage expansion option.
3. Replace blade storage expansion option.
1. Check BladeCenter power (see IBM BladeCenter Type 8677
Hardware Maintenance Manual and Troubleshooting Guide).
2. Reseat blade storage expansion option.
3. Replace blade storage expansion option.
1. Check BladeCenter power (see IBM BladeCenter Type 8677
Hardware Maintenance Manual and Troubleshooting Guide).
2. Reseat blade storage expansion option.
3. Replace blade storage expansion option.
Chapter 6. Symptom-to-FRU index