Power Supply Cord
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Direct
Wire
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
1.
Disconnect power.
2.
Remove the hold-down screw and terminal block cover.
A B
C
D
E
F
A. lbrt'Mnal
bk)ck
cover
B. Exte'rnal ground
conductor
5cre'_,v
C. Cc'nte¢; silver-colore'd
terminal
block
scre'w
D. Hold<town
scre'w location
E. Neutral
ground
wir_"
I. Hole below
tert:'linal
block
opening