3.
Connect
the other wires to outer terminal
block
screws. Tighten
screws.
!! !!
4.
Tighten
strain relief screws.
5.
Insert tab of terminal
block
cover into slot of dryer rear panel. Secure cover with
hold-
down
screw.
6.
Connect
a separate
copper
ground
wire from the external
ground
conductor
screw to an
adequate
ground.
Fire Hazard
Use a heavy
metal
vent.
Do not use a plastic
vent.
Do not use a metal
foil vent.
Failure
to follow
these
instructions
can result
in death
or fire.
WARNING:
Io reduce the risk of fire, this dryer MUSF BE EXHAUSTED
OUTDOORS.
IMPORTANT:
Observe
all governing
codes and ordinances.
The dryer exhaust
must not be connected
into any gas vent, chimney,
wall, ceiling
or a
concealed
space of a building.
If using an existing
vent
system
Clean
lint from the entire
length of the system and make sure exhaust
hood
is not plugged
with
lint.
Replace any plastic or metal foil vent with
rigid or flexible
heavy metal vent.
Review Vent system chart. Modify
existing
vent system if necessary
to achieve
the best
drying
performance.
If this is a new
vent
system
Vent
material
Use a heavy metal vent. Do not use plastic or metal foil vent,
4" (10,2 cm) heavy metal exhaust
vent and clamps
must be used.
4" ( 10.2 cm) heavy metal _'xhaust vent
Vent products
can be purchased
from your dealer or by calling
Maytag Services.
For more
information,
see the "Assistance
or Service"
section.
Rigid metal vent
For best drying
performance,
rigid metal vents are recommended.
Rigid metal vent is recommended
to avoid crushing
and kinking.
Flexible
metal vent
Flexible
metal vents are acceptable
only if accessible
for cleaning.
Flexible
metal vent must be fully extended
and supported
when the dryer is in its final
location.
Remove excess flexible
metal vent to avoid sagging
and kinking
that may result in
reduced
airflow
and poor performance.
Do not install flexible
metal vent in enclosed
walls,
ceilings
or floors.
Elbows
45 ° elbows
provide
better airflow
than 90 ° elbows.
Clamps
Good
Better
Use clamps
to seal all joints.