Electrical Connection - U.s.a. Only - Maytag MED6600TQ - 27 Inch Electric Washer Use & Care Manual

Bravos steam fabric care system electric dryer
Table of Contents

Advertisement

Available languages

Available languages

[]
[]
If local codes do not permit
the connection
of a neutral
ground
wire to the neutral
wire,
see "Optional
3-wire
connection"
in "Electrical
Connection
- U.S.A. Only"
section.
A 4-wire
power supply
connection
must be used when the appliance
is installed
in a
location
where
grounding
through
the neutral
conductor
is prohibited.
Grounding
through
the neutral
is prohibited
for (I) new branch-circuit
installations,
(2) mobile
homes, (3) recreational
vehicles,
and (4) areas where
local codes prohibit
grounding
through
the neutral
conductors.
If using a power
supply
cord:
Use a U[. listed power
supply
cord kit marked
for use with
clothes
dryers. The kit should
contain:
[]
A UL listed 30-amp
power supply
cord, rated 120/240
volt minimum.
The cord should
be
type SR[]) or SRDT and be at least 4 ft (1.22 m) long. The wires that connect
to the dryer
must end in ring terminals
or spade terminals
with
upturned
ends.
[]
A UL listed strain relief.
If your outlet looks like this:
4-wire
re'ceptacle"
(14-30R)
Then choose
a 4-wire
power
supply
cord with
ring or spade terminals
and UI. listed strain
relief. The 4-wire
power
supply
cord, at least 4 ft (1.22 m) long, must have four 10-gauge
copper
wires and match a 4-wire
receptacle
of NEMA Type 14-30R.
The ground
wire (ground
conductor)
may be either
green or [)are. The neutral
conductor
must be identified
by a white
cover.
If your outlet looks like this:
If connecting
by direct wire:
Power supply
cable must match power supply
(4-wire
or 3-wire)
and be:
[]
Flexible
armored
cable or nonmetallic
sheathed
copper
cable (with ground
wire),
protected
with
flexible
metallic
conduit.
All current-carrying
wires must be insulated.
[]
10-gauge
solid copper
wire (do not use aluminum).
[]
At least 5 ft (1.52 m) long.
GROUNDING
INSTRUCTIONS
[] For a grounded,
cord-connected
dryer:
This dryer
must be grounded.
In the event of malfunction
or
breakdown,
grounding
will reduce
the risk of electric
shock
by providing
a path of least resistance
for electric
current.
This dryer
uses a cord
having
an equipment-grounding
conductor
and a grounding
plug. The plug must be plugged
into an appropriate
outlet
that is properly
installed
and
grounded
in accordance
with all local codes and ordinances.
[] For a permanently
connected
dryer:
This dryer
must be connected
to a grounded
metal,
permanent
wiring
system,
or an equipment-grounding
conductor
must be run with the circuit
conductors
and
connected
to the equipment-grounding
terminal
or lead on
the dryer.
WARNING:
Improper
connection
of the equipment-
grounding
conductor
can result in a risk of electlic
shock.
Check
with a qualified
electrician
or service
representative
or personnel
if you are in doubt
as to whether
the dryer is
properly
grounded.
Do not modify
the plug on the power
supply
cord:
if it will not fit the outlet,
have a proper
outlet
installed
by a qualified
electrician.
SAVE THESE
INSTRUCTIONS
3-wire" re'ceptacle"
(lO-30R)
Then choose
a 3-wire
power
supply
cord with
ring or spade terminals
and UL listed strain
relief. The 3-wire
power
supply
cord, at least 4 ft (1.22 m) long, must have three 10-gauge
copper
wires and match a 3-wire
receptacle
of NEMA
t_/pe 10-30R.
6