TANDBERG MXP F8 Administrator's Manual page 223

Table of Contents

Advertisement

MXP
Contents
Introduction
MENU ADDRESS
SETTINGS DESCRIPTION
Control Panel >
NETWORK
Network >
When using the Network Profiles 5, 6 and 7 you can make a Network selection for the profile.
NETWORK PROFILES
AUTO: When set to Auto the system will parse (analyze) the number to dial and decide what network to use
based on this
H.320: Select H.320 for an ISDN network
H.323: Select H.323 for an IP network
SIP: Select SIP for a SIP network
Control Panel >
BAUD RATE, PARITY, DATA BITS, STOP BITS
Network >
The system provides 1 - 2 standard RS232 serial ports to allow a computer to be connected for data transfer
and control purposes.
DATA PORT
Note! When connecting to a PC, the connecting cable must be a straight through RS232 cable.
Configure the settings as required for your application:
Baud Rate (bps): 1200 - 115200
Parity:
Databits:
Stopbits:
Control Panel >
DATA PORT MODE
CONTROL: Gives command access, with the same interface as telnet or ssh. This is the default mode.
Network >
DATA PORT
TRANSPARENT: Line based text interface to far end in point to point call. The far end must also have
transparent mode enabled.
DIRECT: Raw data interface to far end in point to point call. The far end must also have direct mode enabled.
Any data received on the local serial port is transmitted without change to the far end serial port.
OFF: Turns the data port Off.
Control Panel >
DATA PORT 2 SETTINGS AND MODE
Network >
Data port 2 is dedicated to the main camera and will not be available in standard configuration.
DATA PORT 2
The system will automatically detect Precision HD Camera and WAVE camera. At least one of the
cameras must be connected to the data port 2. All communications settings, except the Mode setting, are
automatically configured. Exception: If Mode is Auto and no camera is connected to the Data port 2, the
Baud rate, Parity, Data bits and Stop bits settings will be enabled.
VISCA: Select VISCA mode if the camera support the VISCA protocol.
AUTO: Select Auto and the system will automatically detect the Precision HD Camera or WAVE cameras.
D14033.06—AUGUST 2010
Getting started
The menu structure
The settings library
The settings library
None, Odd, Even
7, 8
1, 2
Using the system
Physical interfaces
Peripheral equipment
INFORMATION
Some systems do not have ISDN (H.320). This applies to the
1700 MXP and NET versions of 3000/990/880 MXP.
A successfully connection of a PC to Data Port 1 requires that
the PC and the system are identically configured.
The control interface provided by the Data Port supports a
subset of the Hayes command set, as well as a comprehensive
set of system specific commands.
It maintains communication with the Data Port's command
interpreter at all times. All features available from the hand-held
remote control can be accessed through the Data Port.
VISCA™ is a trademark of Sony Corporation
Administrator Guide
Appendices
Contact us
PRODUCT
All MXP
systems
8000
6000
Maestro
3000
Tactical
1700
990/880/
770
550
95/85/75
8000
6000
Maestro
223