Installing Non-Hot-Swap Hard Disk Drives - IBM 8647 - Eserver xSeries 225 Maintenance And Troubleshooting Manual

Hardware maintenance manual
Hide thumbs Also See for 8647 - Eserver xSeries 225:
Table of Contents

Advertisement

6. If you are installing additional hot-swap hard disk drives, do so now; otherwise,
7. Make sure that the side cover is unlocked; then, insert the hot-swap lock bar
8. Hold the hot-swap lock bar in the closed position, lock the side cover key lock,
The hot-swap-drive backplane controls the SCSI IDs for the internal hot-swap drive
bays. The SCSI ID for each hot-swap hard disk drive is printed on the hot-swap
lock bar. Table 6 lists the SCSI IDs for the hard disk drives and backplane that are
connected to one channel in hot-swap hard disk drive models. In the typical
configuration, the standard hard disk drives and backplane are connected to
channel A.

Installing non-hot-swap hard disk drives

Bays 4, 5, and 6 are in the drive cage. The drive cage is behind the front of the
adapter-support bracket. Drives are installed starting at the bottom in bay 7.
Additional drives are then installed in bays 6, 5, and 4.
Notes:
1. You can install up to four non-hot-swap hard disk drives in your server. The
2. When installing non-hot-swap hard disk drives, you might find it easier to lay the
Complete the following steps to install a drive in bay 4, 5, or 6:
54
IBM xSeries 225 Type 8647: Hardware Maintenance Manual and Troubleshooting Guide
Note: If your server is configured for RAID operation using the integrated SCSI
controller with RAID capabilities or an optional ServeRAID controller, you
might need to reconfigure your disk arrays after installing hard disk
drives. See the ServeRAID documentation on the IBM ServeRAID
Support CD for additional information on RAID operation and complete
instructions for using ServeRAID Manager.
continue with step 7
into the slots on the front bezel and rotate it to the locked position.
and close the server door.
Table 6. SCSI IDs for standard hot-swap hard disk drives and backplane
Device
Drive bay 9
Drive bay 8
Drive bay 7
Drive bay 6
Drive bay 5
Drive bay 4
Backplane
additional space in the drive cage above bay 4 is not designed to accommodate
any additional drives.
server on its side. If you do so, and your server has stabilizing feet that rotate,
move the feet inward toward the server, so that they do not break.
1. Review the safety information beginning on page 131 and "Installation
guidelines" on page 37
2. Turn off the server and all attached devices.
3. Disconnect all power cords; then, disconnect all external cables.
4. Remove the side cover (see "Removing the side cover" on page 41).
SCSI ID
0
1
2
3
4
5
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xseries 225 type 8647

Table of Contents