Configuring Data Destinations and Categories

Configuring the Data Categories

There are two steps in defining the data categories:
Options
The following options are available:
From the SCE(config)# prompt, type
Step 1
category-name, and press Enter.
Defines the name for the specified category number. This category name can then be used in any
rdr-formatter command instead of the category number.

How to Configure a Destination and Assign Categories

Options
The following options are available:
General Guidelines:
Cisco SCE 2000 and SCE 1000 Software Configuration Guide
8-8
Define the category names (optional).
Configuring the destinations with the proper priorities for each category, as well as configuring all
the other destination parameters, may be approached in several different ways, and may take some
planning. Refer to the examples below for illustrations of some of the issues involved in configuring
categories.
category-number — the number of the category (1-4)
category-name — the name to be assigned to the category
Options, page 8-8
Configuring the Data Destinations with Categories: Examples, page 8-9
ip-address — the IP address of the destination
portnumber — the port number
category-number — the number of the category (1-4)
category-name — the name to be assigned to the category
priority — the priority value assigned to this category for this destination (1-100)
protocol — the protocol used for data sent to the destination (either RDRv1 or NetFlow; if no
protocol is assigned the protocol is RdrV1)
transport — the transport type, TCP or UDP (optional, as this parameter is determined by the
protocol)
A maximum of four categories can be configured in one command.
The category may defined by either number or name.
A different priority may be assigned to each category.
Note that within each category the priorities must be unique for each destination.
Chapter 8
Raw Data Formatting: The RDR Formatter and NetFlow Exporting
rdr-formatter category number
category-number
name
OL-7827-12