Table 3-9
Keyword
ntt
vn3
ISDN PRI
primary-4ess
primary-5ess
primary-dms100
primary-net5
primary-ni
primary-ntt
primary-ts014

Verify

To verify you have configured the interfaces correctly:
ISDN Switch Types for BRI and PRI Interfaces (Continued)
Switch Type
Japanese NTT ISDN switches
French VN3 and VN4 ISDN BRI switches
AT&T 4ESS switch type for the U.S.
AT&T 5ESS switch type for the U.S.
NT DMS-100 switch type for the U.S.
European, New Zealand and Asia ISDN PRI switches (covers the Euro-ISDN E-DSS1
signaling system and is ETSI-compliant)
AT&T National ISDN switch type
Japanese ISDN PRI switches
Australia PRI switches
Enter the show controller t1 or show controller e1 command and specify the port number.
Verify the controller is up and that you do not have excessive errors otherwise your controller
might be going down frequently. This could indicate switch problems.
5300# show controller t1 0
T1 0 is up.
No alarms detected.
Framing is ESF, Line Code is AMI, Clock Source is Line Primary.
Version info of slot 2:
Data in current interval (476 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
Total Data (last 24 hours)
0 Line Code Violations, 0 Path Code Violations,
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
5300# sh cont e1 2
E1 2 is up.
Applique type is Channelized E1 - balanced
No alarms detected.
Version info of Slot 0:
Manufacture Cookie Info:
EEPROM Type 0x0001, EEPROM Version 0x01, Board ID 0x43,
Board Hardware Version 1.0, Item Number 73-2218-3,
Board Revision A0, Serial Number 05823468,
PLD/ISP Version 0.0, Manufacture Date 9-Oct-1997.
Framing is CRC4, Line Code is HDB3, Clock Source is Line Primary.
Data in current interval (701 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
Data in Interval 1:
0 Line Code Violations, 0 Path Code Violations
HW: 2, Firmware: 14, NEAT PLD: 13, NR Bus PLD: 19
HW: 2, Firmware: 4, PLD Rev: 0