HP 195294-001 - ProLiant - ML370R Setup And Installation Manual page 207

Hp proliant ml370 generation 3 setup and installation guide
Hide thumbs Also See for 195294-001 - ProLiant - ML370R:
Table of Contents

Advertisement

Server Error Messages
Table C-1: POST Error Messages
Error Code
207-Invalid Memory
Configuration -
Unsupported DIMM In
DIMM Socket X
Only ECC DIMMs Are
Supported.
207-Invalid Memory
Configuration -
Unsupported DIMM In
DIMM Socket X
DIMM Size Parameters
Not Supported.
207-Invalid Memory
Configuration - DIMMs
must be installed
sequentially.
207-Invalid Memory
Configuration -
Incomplete bank
detected in bank X
207-Invalid Memory
Configuration –
Mismatched DIMMs
within DIMM Bank
Memory in Bank X Not
Utilized.
207-Memory
Configuration Warning –
DIMM in DIMM Socket X
does not have Primary
Width of 4 and only
supports standard ECC.
C-2
continued
Audible
Probable Source
Beeps
of Problem
One long,
Installed DIMMs do not
and one short
have ECC capability.
One long,
Installed DIMMs in the
and one short
same bank are of
different sizes.
One long,
Installed DIMMs are not
and one short
sequentially ordered.
One long,
Bank is missing a
and one short
DIMM.
One long,
Installed DIMMs in the
and one short
same bank are of
different sizes.
One long,
Installed DIMMs have a
and one short
primary width of x8.
HP ProLiant ML370 Generation 3 Server Setup and Installation Guide
Action
Replace DIMMs in
indicated slots.
Refer to "Memory" in
Chapter 3.
Replace DIMMs in
indicated slots.
Refer to "Memory" in
Chapter 3.
Reinstall DIMMs in
proper order.
Refer to "Memory" in
Chapter 3.
Install a DIMM to fill the
bank.
Refer to "Memory" in
Chapter 3.
Replace DIMMs in
indicated slots.
Refer to "Memory" in
Chapter 3.
Install DIMMs that have
a primary width of x4.
Refer to "Memory" in
Chapter 3.
continued