LTS (Label Taken Sensor)

LTS Adjust

LTS Test

LTS Value

EasyCoder PM4i Printer User's Guide (Fingerprint Version)
The sensitivity of the LTS may need to be adjusted according to
ambient light conditions and reflective characteristics of the back
side of the media. This is done in the Setup Mode (Print Defs/
LTS), see Chapter 7. You can also check that the LTS works
properly.
The LTS setup options are only displayed if an optional label
taken sensor is installed in the printer.
Press Enter. A label is fed out. Remove the label and press Enter
again. A menu shows the sensitivity automatically selected by the
firmware and the range, in which the LTS will work. Press Enter
again and you will proceed to the LTS Test menu.
Press Enter. A label is fed out. Remove the label and a new label
should be fed out automatically. Repeat until you are sure the
LTS works properly. Then press Enter to stop and exit.
Press Enter. You can enter a new value in the range indicated in
the LTS Adjust menu (see above). Min/max values are in the
range 0 to 10.