Chapter 6
Setting Up the Printer
Setup Parameters, cont.
Print Defi nes, cont.
52

LTS (Label Taken Sensor)

The sensitivity of the LTS may need to be adjusted according to
ambient light conditions and refl ective characteristics of the back
side of the media. The LTS setup options are only displayed if an
optional label taken sensor is installed in the printer.
• LTS Adjust
Press <Enter>. A label is fed out. Remove the label and press
<Enter> again. A menu shows the sensitivity automatically
selected by the fi rmware and the range, in which the LTS will
work. Press <Enter> again and you will proceed to the LTS
Test menu.
• LTS Test
Press <Enter>. A label is fed out. Remove the label and a
new label should be fed out automatically. Repeat until you
are sure the LTS works properly. Then press <Enter> to stop
and exit.
• LTS Value
Press <Enter>. You can enter a new value in the range indi-
cated in the LTS Adjust menu (see above). Min/max values
are in the range 0 to 10.