Error Message and Recovery Procedures
Error Message CDP-4-NATIVE_VLAN_MISMATCH: Native VLAN mismatch discovered on [chars]
([dec]), with [chars] [chars] ([dec]).
Explanation
Recommended Action

CHASSIS Message

This section contains the chassis error message.
Error Message CHASSIS-5-BLADE_EXTRACT
Explanation
Recommended Action

CMP Messages

This section contains the Cluster Membership Protocol error messages.
Error Message CMP-5-ADD: The Device is added to the cluster (Cluster Name:[chars],
CMDR IP Address [inet])
Explanation
and [inet] is the Internet address of the command switch.
Recommended Action
Error Message CMP-5-MEMBER_CONFIG_UPDATE: Received member configuration from member
[dec]
Explanation
the member number.
Recommended Action
Error Message CMP-5-REMOVE The Device is removed from the cluster (Cluster
Name:[chars])
Explanation
name.
Recommended Action
Catalyst 2900 Series XL and Catalyst 3500 Series XL Software Configuration Guide
A-8
CDP discovered a mismatch of native-VLAN configurations.
Configure the interfaces to the same native VLAN.
The message means that the hot-swap switch has been pressed.
Extract the module.
The message means that the device is added to the cluster: [chars] is the cluster name,
No action is required.
This message means that the command switch received a member configuration: [dec] is
No action is required.
The message means that the device is removed from the cluster: [chars] is the cluster
No action is required.