Mechanical Installation - Omron V1000 Quick Start Manual

Compact current vector inverter
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

2

Mechanical Installation

Upon Receipt
Please perform the following tasks after receiving the drive:
• Inspect the drive for damage. If the drive appears damaged upon receipt, contact your sup-
plier.
• Verify receipt of the correct model by checking the information on the nameplate. If you
have received the wrong model contact your supplier.
Installation Environment
For optimum performance life of the drive, install the drive in an environment that meets the
conditions listed below.
Environment
Installation Area
Ambient Temperature
Humidity
Storage Temperature
Surrounding Area
Altitude
Vibration
Orientation
I67E-EN
V1000 Quick Start Guide
Indoors
°
°
-10
C to +40
C (NEMA Type 1)
°
°
-10
C to +50
C (Open-Chassis Type)
When using an enclosure panel, install a cooling fan or air conditioner in the
area to ensure that the air temperature inside the enclosure does not exceed the
specified levels.
Do not allow ice to develop on the drive.
95% RH or less and free of condensation
°
°
-20
C to +60
C
Install the drive in an area free from:
• oil mist and dust
• metal shavings, oil, water or other foreign materials
• radioactive materials
• combustible materials (e.g., wood)
• harmful gases and liquids
• excessive vibration
• chlorides
• direct sunlight
1000 m or less
10 - 20 Hz at 9.8 m/s
2
, 20 - 55 Hz at 5.9 m/s
Install the drive vertically to maintain maximum cooling effects.
2 Mechanical Installation
Conditions
2
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V1000 vza series

Table of Contents