Design
3-1

Installation

3-1-1 Outside/Mounting Dimensions

Note
All dimensions are in millimeters.
H 3G3EV-A2001(M)-CUE to 3G3EV-A2004(M)-CUE (0.1 to 0.4 kW):
Three-phase 200-VAC Input
H 3G3EV-AB001(M)-CUE to 3G3EV-AB002(M)-CUE (0.1 to 0.2 kW):
Single/Three-phase 200-VAC Input
Note 1. For the 3G3EV-A2001(M)-CUE, 3G3EV-A2002(M)-CUE, and 3G3EV-AB001(M)-CUE, a U-
shaped notch (4.5 mm wide) is provided instead of the upper mounting hole (4.5 mm in diame-
ter).
Note 2. Install the Inverter with two M4 bolts.
D Three-phase 200-VAC Input Model
3G3EV model
Output
A2001(M)-CUE
0.1 kW
A2002(M)-CUE
0.2 kW
A2004(M)-CUE
0.4 kW
3-2
4.5 dia.
W
H
68
128
75
88
110
D
W1
H1
56
118
Chapter 3
T
Weight
(kg)
3
Approx.
0.5
3
Approx.
0.6
5
Approx.
0.9