5 Start Up
For Auto-Tuning enter the Auto-Tuning menu and perform the steps shown in the figure
below. The number of name plate data to be entered depends on the selected type of Auto-
Tuning. This example shows Rotational Auto-Tuning.
Drive mode
Enter the Auto-
Select the tuning
display
Tuning Mode
method
Set up all name
The tuning start
During the tuning the
After successful tuning
plate data
display appears
DRV LED flashes
"End" is displayed
If Auto-Tuning can not be performed for some reason (no-load operation impossible etc.),
then set up the maximum frequency and voltage in the E1-
parameters and enter the
motor data manually into the E2-
parameters.
NOTICE! The Safe Disable inputs must be closed during Auto-Tuning.