Default System Tags
1. System Registers
Tags
Tag Name
S0001
Language
S0003_14
Comm1 status
S0003_15
Comm2 status
S0004
Number of Historical
S0005
Screen Trigger
S0007
Battery Voltage
S0008
Error code for
Xtradrive Com1
S0009
Error code for
Xtradrive Com2
2. System Bits
Tags
Tag Name
s0009
Beeper On /Off
s0010
Battery Status
s0011
Start / Stop jog
s0013
Start / Stop jog
Read / Write
Read / Write
Writing the value will change languages
used in any wizard
Read Only
0 = Communication Error
1 = Communicating with PLC
Read Only
0 = Communication Error
1 = Communicating with PLC full status
Read Only
Shows number of alarms stored in
memory Alarms
Read / Write
Shows active screen no. User can
change Register screen by writing any
valid screen no in this register
Read Only
Indicates battery voltage in #.# format
Read only
Error code byte for Xtradrive for Com1
Read only
Error code byte for Xtradrive for Com2
Read / Write
Read / Write
0: Enable Beeper
1: Disable Beeper
User can change this bit at Run time.
Read only
0: Battery voltage is OK (i.e.above 2.2 V)
1: Low Battery (i.e. below 2.2V)
Read / Write
Used in jog operation of Xtradrive for port1
for Xtradrive Com1
1: Continuous jog operation on port1
0: Stop jog operation on port1
Read / Write
Used in jog operation of Xtradrive for port2
for Xtradrive Com2
1: Continuous jog operation on port2
0: Stop jog operation on port2
Using NTXS Software
Description
Description
53